BOLD MRI Can Detect Coronary Stenosis at Rest

By MedImaging International staff writers
Posted on 26 Jul 2016
Print article
Image: A patient about to undergo an MRI scan (Photo courtesy of MNT).
Image: A patient about to undergo an MRI scan (Photo courtesy of MNT).
A new study suggests that blood oxygen-level dependent (BOLD) magnetic resonance imaging (MRI) can detect myocardial ischemia without inducing cardiac physiological or pharmacological stress.

Researchers at John Radcliffe Hospital (Oxford, United Kingdom) conducted a study to reevaluate data published in 2012 that focused more on segment-based analysis of BOLD, whereas the new analysis focused on whole-slice analysis. In the first study, which included 25 coronary artery disease (CAD) patients and 20 healthy volunteers, the researchers determined the diagnostic performance of stress BOLD imaging in identifying significant CAD.

For the present analysis, resting BOLD signal intensity was first evaluated in the derivation group, and then tested in a separate validation group of 57 patients with suspected CAD referred for diagnostic coronary angiography. The range of BOLD signals at rest for each patient was indexed to create a score that correlated with presence of CAD, with an average index of 22.6% in those with versus 15.4% for those without ischemia. The researchers therefore defined a 16.1% cutoff score that identified ischemia-causing blockages.

Upon validation, the researchers found that the BOLD model could identify blockages with 88% sensitivity, 58% specificity, and 75% overall diagnostic accuracy. It performed similarly for diagnosing anatomically-significant CAD--defined as 50% or greater stenosis--at 82% sensitivity, 61% specificity, and 75% overall diagnostic accuracy. The researchers also concluded that BOLD MRI could perform equally well at stress as at rest. The study was published in the July 2016 issue of JACC: Cardiovascular Imaging.

“Our findings are pertinent to alternative imaging modalities with the potential to identify microvascular heterogeneity, and advance the concept of a functional assessment of CAD being performed at rest,” concluded lead author Jayant Ranjit Arnold, BMBCh, MA, and colleagues. “The inability of resting myocardial blood flow to discriminate the presence of CAD indicates that the favorable diagnostic performance of resting BOLD assessment is not dependent on changes in resting myocardial blood flow.”

BOLD MRI measures the blood oxygen level dependent signal that is associated with changes in blood flow and oxygenation following neural activity. The technique is particularly helpful in neurology for patients with premotor symptoms of Parkinson’s disease (PD) such as frontal executive dysfunction. The neuroimaging provides excellent resolution and diagnostic sensitivity, and can facilitate the diagnosis of other neurodegenerative conditions, including multiple system atrophy, corticobasal degeneration, and progressive supranuclear palsy.

Related Links:
John Radcliffe Hospital


Gold Member
Solid State Kv/Dose Multi-Sensor
AGMS-DM+
Ultrasound System
P25 Elite
Advanced Cardiac MRI Analysis Software
3Di Cardiac MR
New
Oncology Information System
RayCare

Print article

Channels

Ultrasound

view channel
Image: Structure of the proposed transparent ultrasound transducer and its optical transmittance (Photo courtesy of POSTECH)

Ultrasensitive Broadband Transparent Ultrasound Transducer Enhances Medical Diagnosis

The ultrasound-photoacoustic dual-modal imaging system combines molecular imaging contrast with ultrasound imaging. It can display molecular and structural details inside the body in real time without... Read more

Nuclear Medicine

view channel
Image: PET/CT of a 60-year-old male patient with clinical suspicion of lung cancer (Photo courtesy of EJNMMI Physics)

Early 30-Minute Dynamic FDG-PET Acquisition Could Halve Lung Scan Times

F-18 FDG-PET scans are a way to look inside the body using a special dye, and these scans can be either static or dynamic. Static scans happen 60 minutes after the dye is administered into the body, showing... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more

Industry News

view channel
Image: The acquisition will expand IBA’s medical imaging quality assurance offering (Photo courtesy of Radcal)

IBA Acquires Radcal to Expand Medical Imaging Quality Assurance Offering

Ion Beam Applications S.A. (IBA, Louvain-La-Neuve, Belgium), the global leader in particle accelerator technology and a world-leading provider of dosimetry and quality assurance (QA) solutions, has entered... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.