Obese Patients Are Exposed to Higher Radiation Doses

By MedImaging International staff writers
Posted on 10 Jan 2019
Print article
Image: A new study claims that obese patients are exposed to more radiation (Photo courtesy of University of Exeter).
Image: A new study claims that obese patients are exposed to more radiation (Photo courtesy of University of Exeter).
A new study finds that obese patients face an increased radiation-related lifetime cancer risk due to higher dose area product (DAP) radiation exposures.

Researchers at the University of Exeter (United Kingdom), Musgrove Park Hospital (Taunton, United Kingdom), and Derriford Hospital (Plymouth, United Kingdom) conducted a study involving 630 patients from a bariatric clinic who had a projection radiography history. The prime purpose of the study was to evaluate X-ray radiation dose delivered to obese patients, and its relationship to patient size. A secondary purpose was to estimate subsequent projected radiation-related lifetime cancer risk in patients with obesity.

Patients' DAP data were collected for all projection radiography, and the effective risk for patients with obesity was then compared to that of normal-weight patients. The results showed that patients with obesity received higher DAPs for all examinations, with the highest DAPs in abdominal and lumbar spine radiographs. In abdomen and chest x-rays, there were moderate-to-low correlations between patient size and DAP. The projected radiation-related lifetime cancer risk was up to 153% higher than in normal-weight adult patients. The study was published on December 20, 2018, in the Journal of Radiological Protection.

“As a researcher and a radiographer, I believe these radiation doses figures are only to be expected due to the lack of guidelines to aid imaging this group of patients,” said lead author Saeed Alqahtani, MD, of the University of Exeter, and colleagues. “As well as the doses of radiation given to the patient, many technical factors contribute to the image quality of an X-ray. We already started working on this issue in an attempt to produce prediction models that can aid radiographers to choose the best technical factors based on the patient's size.”

DAP reflects not only the dose within the radiation field but also the area of tissue irradiated. Therefore, it may be a better indicator of the overall risk of inducing cancer than the dose within the field. It also has the advantages of being easily measured, with the permanent installation of a DAP meter on the X-ray set. Due to the divergence of a beam emitted from a point source, the area irradiated increases with the square of distance from the source, while radiation intensity decreases according to the inverse square of distance. Consequently, the product of intensity and area, and therefore DAP, is independent of distance from the source.

Related Links:
University of Exeter
Musgrove Park Hospital
Derriford Hospital

Gold Member
Solid State Kv/Dose Multi-Sensor
AGMS-DM+
Imaging Table
Stille imagiQ2
Advanced Cardiac MRI Analysis Software
3Di Cardiac MR
MRI System
uMR 588

Print article

Channels

Ultrasound

view channel
Image: Structure of the proposed transparent ultrasound transducer and its optical transmittance (Photo courtesy of POSTECH)

Ultrasensitive Broadband Transparent Ultrasound Transducer Enhances Medical Diagnosis

The ultrasound-photoacoustic dual-modal imaging system combines molecular imaging contrast with ultrasound imaging. It can display molecular and structural details inside the body in real time without... Read more

Nuclear Medicine

view channel
Image: PET/CT of a 60-year-old male patient with clinical suspicion of lung cancer (Photo courtesy of EJNMMI Physics)

Early 30-Minute Dynamic FDG-PET Acquisition Could Halve Lung Scan Times

F-18 FDG-PET scans are a way to look inside the body using a special dye, and these scans can be either static or dynamic. Static scans happen 60 minutes after the dye is administered into the body, showing... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more

Industry News

view channel
Image: The acquisition will expand IBA’s medical imaging quality assurance offering (Photo courtesy of Radcal)

IBA Acquires Radcal to Expand Medical Imaging Quality Assurance Offering

Ion Beam Applications S.A. (IBA, Louvain-La-Neuve, Belgium), the global leader in particle accelerator technology and a world-leading provider of dosimetry and quality assurance (QA) solutions, has entered... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.