MDCT Radiation Dose Can Be Reduced by the Use of Pediatric Breast Shields

By MedImaging staff writers
Posted on 26 Feb 2008
Print article
Image: 3-D CT of a child’s head, showing the skin surface (orange) and the skull (blue) (Photo courtesy of Philippe Plailly / SPL).
Image: 3-D CT of a child’s head, showing the skin surface (orange) and the skull (blue) (Photo courtesy of Philippe Plailly / SPL).
Using breast shields during pediatric chest multi-detector computed tomography (MDCT) imaging reduces radiation dose and minimally increases image noise, according to a recent study.

The study was conducted by researchers at Duke University Medical Center (Durham, NC, USA) and the University of Arkansas for Medical Sciences and Arkansas Children's Hospital (Little Rock, USA).

"It's important for radiologists to limit dose in CT, especially to children, and especially to radiosensitive regions, such as breast tissue; and radiologists should be familiar with strategies to do this,” said Donald P. Frush, M.D., lead author of the study. "Two strategies are breast shielding, and the other is automatic tube current modulation [ATCM]. However, the combination of the shield and ATCM may not be effective since the equipment might increase the dose to penetrate the shield. We wanted to see if there was a way to circumvent this, and in fact, there was: by placing the shields on the patient after the topogram [scout] from which the tube current would be modulated. This was tested using a GE [Healthcare] scanner [Chalfont St. Giles, UK] and it may not work with other scanners.”

Researchers performed MDCT on the chest an anthropomorphic phantom that represented a five-year-old child. They obtained two scans in each of four sequences: without the shield, with a two-ply bismuth shield, ATCM after placement of the shield, and ATCM before placement of the shield.

The study revealed that the bismuth breast shield reduced radiation dose to the breast by 26%, and shielding and ATCM reduced the dose by 52%. The study also showed that multiple organ doses were lowest when the shield was placed after the scout radiograph was obtained. With this technique, image noise increased, but the images were still of good quality.

"Radiologists need to understand their equipment's ATCM before using shielding. Parents should inquire about dose reduction strategies before their child undergoes a CT scan, and physicians who refer pediatric patients to radiologists should understand that research is continuing to minimize radiation dose in CT,” said Dr. Frush.

The full results of this study appear in the January 2008 issue of the American Journal of Roentgenology.


Related Links:
Duke University Medical Center
Arkansas Children's Hospital
New
MRI Infusion Workstation
BeneFusion MRI Station
40/80-Slice CT System
uCT 528
Multi-Use Ultrasound Table
Clinton
Radiology Software
DxWorks

Print article

Channels

MRI

view channel
Image: The AI tool can help interpret and assess how well treatments are working for MS patients (Photo courtesy of Shutterstock)

AI Tool Tracks Effectiveness of Multiple Sclerosis Treatments Using Brain MRI Scans

Multiple sclerosis (MS) is a condition in which the immune system attacks the brain and spinal cord, leading to impairments in movement, sensation, and cognition. Magnetic Resonance Imaging (MRI) markers... Read more

Nuclear Medicine

view channel
Image: In vivo imaging of U-87 MG xenograft model with varying mass doses of 89Zr-labeled KLG-3 or isotype control (Photo courtesy of L Gajecki et al.; doi.org/10.2967/jnumed.124.268762)

Novel Radiolabeled Antibody Improves Diagnosis and Treatment of Solid Tumors

Interleukin-13 receptor α-2 (IL13Rα2) is a cell surface receptor commonly found in solid tumors such as glioblastoma, melanoma, and breast cancer. It is minimally expressed in normal tissues, making it... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.