Digital Wrist Tomosynthesis Assesses Women’s Bone Health

By MedImaging International staff writers
Posted on 08 Feb 2021
A new study shows how digital breast tomosynthesis (DBT) scanners can also be used to perform bone density measurements.

Researchers at Henry Ford Health System (Detroit, MI, USA) conducted a study to explore the feasibility of using DBT devices for digital wrist tomosynthesis (DWT) so as to measure bone mineral density (BMD), cortical bone thickness, and microstructural properties of the wrist bone. The results were then correlated to reference measurements acquired via microcomputed tomography and dual energy x-ray absorptiometry (DXA). The researchers recruited five patients, (19 to 75 years of age), who aligned their left hand on a generic hand template taped to a DBT machine.

The results showed that measurements from DWT imaging with a DBT scanner were highly repeatable; in ex-vivo trials, DWT derived BMDs were strongly correlated with reference measurements, as was the cortical thickness measured at lateral and medial cortices, and the majority of microstructural measures. In-vivo measurements were quick and tolerated well by the volunteer patients with no discomfort, and appeared to be different between young and old participants in a preliminary comparison. The study was published on December 13, 2021, in Bone.

“DWT is feasible in a mammography setting, and informative on bone mass, cortical thickness, and microstructural qualities that are known to deteriorate in osteoporosis. To our knowledge, this study represents the first application of DBT for imaging bone,” concluded lead author Yener Yeni, PhD, and colleagues. “It is reasonable to expect that with increasing adoption of DBT and continued high adherence to breast screening, bone screening would become more prevalent if offered in coordination with DBT breast exams.”

Osteoporosis is defined as a bone density of 2.5 standard deviations below that of a young adult, as measured by DXA. It is the most common reason for a broken bone among the elderly, and may be due to a lower than normal peak bone mass and a greater than normal bone loss. It is more common in women than men, with 2-8% of males and 9-38% of females affected after menopause, usually due to lower levels of estrogen.

Related Links:
Henry Ford Health System


Multi-Use Ultrasound Table
Clinton
Ultrasound Table
Women’s Ultrasound EA Table
Ultrasonic Pocket Doppler
SD1
40/80-Slice CT System
uCT 528
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to MedImaging.net and get complete access to news and events that shape the world of Radiology.
  • Free digital version edition of Medical Imaging International sent by email on regular basis
  • Free print version of Medical Imaging International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of Medical Imaging International in digital format
  • Free Medical Imaging International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

MRI

view channel
Image: Comparison showing 3T and 7T scans for the same participant (Photo courtesy of P Simon Jones/University of Cambridge)

Ultra-Powerful MRI Scans Enable Life-Changing Surgery in Treatment-Resistant Epileptic Patients

Approximately 360,000 individuals in the UK suffer from focal epilepsy, a condition in which seizures spread from one part of the brain. Around a third of these patients experience persistent seizures... Read more

Ultrasound

view channel
Image: The new type of Sonogenetic EchoBack-CAR T cell (Photo courtesy of Longwei Liu/USC)

Smart Ultrasound-Activated Immune Cells Destroy Cancer Cells for Extended Periods

Chimeric antigen receptor (CAR) T-cell therapy has emerged as a highly promising cancer treatment, especially for bloodborne cancers like leukemia. This highly personalized therapy involves extracting... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.