We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
GLOBETECH PUBLISHING LLC

Download Mobile App




Radiation Beam Imaging System Observes RT in Action

By MedImaging International staff writers
Posted on 10 Aug 2018
Print article
Image: A novel imaging system visualizes RT in real time (Photo courtesy of DoseOptics).
Image: A novel imaging system visualizes RT in real time (Photo courtesy of DoseOptics).
A novel imaging system provides real-time visualization of radiotherapy (RT) beam shape at the point of incidence and exit.

The DoseOptics (Lebanon, NH, USA) C Dose RESEARCH camera uses unique time-gating video technology to capture both photon and electron beam delivery and ensure that each pulse of the linear accelerator contributes to the image, with time-integrating software allowing a cumulative image that can be overlaid in real time on the object being irradiated. Information on RT cone position, gantry movements, and the multi-leaf collimator (MLC) jaw are recorded simultaneously. The camera and software operate remotely, providing an independent check and measurement tool for both beam shape and delivery.

The C Dose RESEARCH camera is based on detection of Cherenkov radiation, an electromagnetic (EM) radiation emitted when a charged particle (such as an electron) passes through a dielectric (phased) medium at a speed that is greater than the phase velocity of light in the same medium. This gives off a visible glow. One such example of Cherenkov radiation is the characteristic blue glow emitted by an underwater nuclear reactor. Cherenkov radiation is named after Soviet scientist Pavel Cherenkov, who won the 1958 Nobel Prize in physics.

“We are extremely excited to be able to offer a Cherenkov imaging system to the field of radiation oncology where we believe it can change the paradigm of radiation delivery verification, and provide intuitive visualization of the treatment for everyone in the department,” said Brian Pogue, MD, PhD, president of DoseOptics. “As new delivery techniques improve and become more and more complex, verification remains a challenge. With C-Dose, medical physicists charged with ensuring delivery accuracy can now literally see what they are doing.”

Current external beam radiation therapy (EBRT) is a “blind” procedure, with patients aligned and imaged via computerized tomography (CT). Treatment plans are generated at the instrument before treatment starts. While EBRT is a highly precise treatment with little room for error, routine verification of targeted RT delivery is not typically done. Major errors are estimated at about 0.2%, and minor errors are likely to occur much more frequently. The consequences can range from skin burns to tissue damage to death.

Related Links:
DoseOptics

New
Gold Member
X-Ray QA Meter
T3 AD Pro
Portable X-ray Unit
AJEX130HN
New
Mini C-arm Imaging System
Fluoroscan InSight FD
Opaque X-Ray Mobile Lead Barrier
2594M

Print article

Channels

MRI

view channel
Image: MRI microscopy of mouse and human pancreas with respective histology demonstrating ability of DTI maps to identify pre-malignant lesions (Photo courtesy of Bilreiro C, et al. Investigative Radiology, 2024)

Pioneering MRI Technique Detects Pre-Malignant Pancreatic Lesions for The First Time

Pancreatic cancer is the leading cause of cancer-related fatalities. When the disease is localized, the five-year survival rate is 44%, but once it has spread, the rate drops to around 3%.... Read more

Ultrasound

view channel
Image: A transparent ultrasound transducer-based photoacoustic-ultrasound fusion probe, along with images of a rat’s rectum and a pig’s esophagus (Photo courtesy of POSTECH)

Transparent Ultrasound Transducer for Photoacoustic and Ultrasound Endoscopy to Improve Diagnostic Accuracy

Endoscopic ultrasound is a commonly used tool in gastroenterology for cancer diagnosis; however, it provides limited contrast in soft tissues and only offers structural information, which reduces its diagnostic... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.