We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
GLOBETECH PUBLISHING LLC

Download Mobile App




Ultrasonic Detection of Liver Stiffness a Useful Screening and Prognostic Test

By MedImaging International staff writers
Posted on 23 Feb 2010
Print article
Researchers from France and Hong Kong determined that transient elastography (TE), a noninvasive, ultrasound imaging modality, can be accurately performed in the majority of patients with nonalcoholic fatty liver disease (NAFLD) to exclude advanced fibrosis.

The findings of this study, funded by the Chinese University of Hong Kong, appear in the February 2010 issue of the journal Hepatology. NAFLD is the most common cause of liver disease worldwide. Determining a prognosis for this condition is difficult, as there are no clear predictors of whether NAFLD will progress to nonalcoholic steatohepatitis (NASH), which can lead to cirrhosis and other complications.

Liver biopsy is the standard for diagnosing NASH and fibrosis, but this procedure can be risky and samples only a small percentage of liver tissue. According to the U.S. National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK), part of the National Institutes of Health (NIH; Bethesda, MD, USA), biopsy carries a small risk of hemorrhage, puncture of other internal organs, infection, and spread of cancer cells. Transvenous liver biopsy carries an additional risk of adverse reaction to the contrast material.

To meet the urgent need for noninvasive alternatives to liver biopsy, a research team led by Victor de Lédinghen, M.D., Ph.D., from the Service d'Hépato-Gastroentérologie, Centre d' Investigation de la Fibrose hépatique, Hôpital Haut Lévesque (Bordeaux, Pessac, France), conducted an evaluation of the accuracy of TE and biochemical tests for the diagnosis of fibrosis and cirrhosis in NAFLD patients. "Transient elastography by Fibroscan is a noninvasive method for the diagnosis of liver fibrosis…Nevertheless, NAFLD patients are underrepresented in previous validation studies,” explained Dr. de Lédinghen. The team also examined liver stiffness in association with hepatic steatosis, inflammation, and obesity, and set out to identify factors associated with discordance between liver stiffness measurements (LSM) and histology.

The Fibroscan technology used in this study was developed by EchoSens (Paris, France). Using the device, a mechanical pulse is generated at the skin surface, which is propagated through the liver. The velocity of the wave is measured by ultrasound. The velocity is directly correlated to the stiffness of the liver, which in turn reflects the degree of fibrosis--the stiffer the liver is the greater the degree of fibrosis. The technique is used to quantify hepatic fibrosis in a totally noninvasive and painless manner, with no contra-indications for the patient.

The research team evaluated 246 patients from two ethnic groups from two hospitals in France and Hong Kong with valid LSM acquisitions and satisfactory liver biopsy specimens. Men who consumed more than 30 g of alcohol per week and women who consumed more than 20 g of alcohol per week were excluded. Patients with secondary causes of hepatic steatosis (e.g., chronic use of systemic corticosteroids), positive hepatitis B surface antigen or anti-hepatitis C virus antibody, or histologic evidence of other concomitant chronic liver diseases were also excluded. Since the aim of transient elastography was to diagnose significant fibrosis and early cirrhosis, patients with clinical and radiologic evidence of cirrhosis were excluded.

Researchers found that successful measurement could be obtained in over 97% of patients with BMI below 30 kg/m2 and 75% of obese patients. LSM was not affected by hepatic steatosis, necroinflammation, and obesity. Most discordance between TE and histology occurred in patients with short liver biopsy lengths and mild or no fibrosis. In addition, TE had superior performance to other noninvasive biochemical tests in diagnosing advanced fibrosis and cirrhosis.

"The adoption of transient elastography could potentially spare two-thirds of NAFLD patients from liver biopsies. Since the prevalence of NAFLD is high in many affluent countries, this approach would be cost-saving,” speculated Dr. de Lédinghen.

Dr. de Lédinghen also cautioned that while TE has a high negative predictive value, the positive predictive value of TE and other noninvasive tests to diagnose advanced fibrosis in NAFLD patients remains modest. He stated, "The main value of these tests is to exclude advanced fibrosis as screening tests. Based on our data, it is reasonable to consider liver biopsy in patients whose LSM is 7.9 kPa or above.”

Prof. Leon Adams, an associate professor at the University of Western Australia (Perth), and author of an editorial in the same issue of Hepatology, agreed, stating, "de Lédinghen et al have provided valuable data regarding the use of TE in NAFLD patients. Its strength appears to be excluding advanced fibrosis and cirrhosis; however, there are a number of issues that need to be clarified before it is routinely utilized in the clinical setting.” Prof. Adams pointed out issues in successfully conducting TE evaluations on obese patients, varying results due to diverse patient populations, and the fact that cost and availability may play a role in the decision to employ TE and other noninvasive tests in the future.

Related Links:
Chinese University of Hong Kong
Hôpital Haut Lévesque
EchoSens
University of Western Australia



New
Gold Member
X-Ray QA Meter
T3 AD Pro
New
Diagnostic Ultrasound System
MS1700C
Imaging Table
CFPM201
New
Digital X-Ray Detector Panel
Acuity G4

Print article
Radcal

Channels

Radiography

view channel
Image: The new X-ray detector produces a high-quality radiograph (Photo courtesy of ACS Central Science 2024, DOI: https://doi.org/10.1021/acscentsci.4c01296)

Highly Sensitive, Foldable Detector to Make X-Rays Safer

X-rays are widely used in diagnostic testing and industrial monitoring, from dental checkups to airport luggage scans. However, these high-energy rays emit ionizing radiation, which can pose risks after... Read more

MRI

view channel
Image: The scans revealed a new dimension of brain network organization in humans (Photo courtesy of Georgia State University/TReNDS Center Research)

New Approach Identifies Signatures of Chronic Brain Disorders Using fMRI Scans

Traditional studies of brain function, often using fMRI scans to detect brain activity patterns, have shown promise in identifying changes in individuals with chronic brain disorders like schizophrenia.... Read more

Nuclear Medicine

view channel
Image: Example of AI analysis of PET/CT images (Photo courtesy of Academic Radiology; DOI: 10.1016/j.acra.2024.08.043)

AI Analysis of PET/CT Images Predicts Side Effects of Immunotherapy in Lung Cancer

Immunotherapy has significantly advanced the treatment of primary lung cancer, but it can sometimes lead to a severe side effect known as interstitial lung disease. This condition is characterized by lung... Read more

General/Advanced Imaging

view channel
Image: Cleerly offers an AI-enabled CCTA solution for personalized, precise and measurable assessment of plaque, stenosis and ischemia (Photo courtesy of Cleerly)

AI-Enabled Plaque Assessments Help Cardiologists Identify High-Risk CAD Patients

Groundbreaking research has shown that a non-invasive, artificial intelligence (AI)-based analysis of cardiac computed tomography (CT) can predict severe heart-related events in patients exhibiting symptoms... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.