Perioperative Ultrasound Monitoring of Radial Artery Catheter Failure

By MedImaging International staff writers
Posted on 09 Jun 2015
Print article
The SonoScape S9 Ultrasound Unit
The SonoScape S9 Ultrasound Unit (Photo courtesy of SonoScape Co., Ltd.)
Using a hand carry ultrasound system, students and staff from the Department of Radiology/Ultrasound and Anesthesiology at Sidney Kimmel Medical College of Thomas Jefferson University recently finished a study of mechanisms related in the cause of radial artery catheter failure.

The study was presented at the 2015 WFUMB/AIUM Convention [UMB 41(4S):S125, 2015]. Radial artery catheters (RAC) are commonly used in the emergency department, operating rooms and critical care units of a hospital to accurately monitor the arterial blood pressure and acquire blood samples.

With the use of SonoScape’s S9 ultrasound system (SonoScape Medical corp.; Shenzhen, China), the researchers hoped to discover why RAC fail prematurely and the causes of complications related to RAC clinical use. The clinical trial was designed to determine the causes of RAC failure and to confirm if a low artery diameter to catheter diameter ratio leads to decreased local blood flow and thrombosis.

For this IRB-approved study, 25 patients requiring a RAC for clinical care were enrolled. To evaluate and monitor the RAC insertions as well as blood flow dynamics in the radial and ulnar arteries, the 25 patients were scanned with the S9 ultrasound system with a 12 MHz linear array probe.

They were scanned before RAC insertion, immediately after, and intermittently every two to four hours during the day and every four to six hours during the night (for 24 to 36 hours). By using the S9 ultrasound, they were able to literally see what was happening in the ulnar and radial arteries of the patients.

Using the S9’s grayscale and Doppler technology, measurements were taken of blood flow and the diameters of both the ulnar and radial arteries. Assessments of RAC insertion factors also allowed for measurements for the composite vessel trauma score for respective arteries after insertion. To analyze the data, a paired Student t-test and a Wilcoxon Rank-Sum test were used to compare results. For the purpose of the study, a RAC initial failure and final failure were classified as difficulty/inability to aspirate blood through the RAC or a dampening/loss of the blood pressure waveform.

Throughout the study, a total of 211 ultrasound scans were obtained from the 25 patients using the S9 ultrasound system. From the 25 patients, 21 experienced a RAC initial failure and four patients experienced a RAC final failure. With the S9’s high image clarity, the reasons for RAC failure were easily revealed. Each failed for a different reason: ranging from the catheter being outside of the vessel and in the subcutaneous tissue, the RA catheter tip was against the arterial wall, thrombus on the catheter tip partially/completely obstructed the RA catheter lumen, and thrombus within the RA lumen partially/completely obstructed RA blood flow.

Soon after RA catheter insertion, the RA and UA inner diameters increased from 2.21±0.4 mm to 2.54±0.45 mm and from 1.91±0.44 mm to 2.23±0.48 mm respectively (no significant differences in RA and UA diameters).

For the 24 RACs that did not have a final failure, the median number of cannulation attempts was 9 and the median CVTS was 8.5. Comparatively, the CVTS for the four RACS that developed a final failure was 8.3 and the mean number of blood draws was 5±3.3. Median time to initial dampening of the RA waveform was 5.9 hours in 22 different cases.

By using the S9’s color Doppler, the team was able to measure the velocities in the RA and UA arteries after RAC insertion. In the RA artery, the peak velocity decreased from 56.2±18.7 to 36.6 cm/s after the RAC was inserted. Peak velocity in the UA however, increased from 53.7±19.3 to 63.4±20.5 cm/s after insertion of the RAC. Ultrasound scans also did not indicate a difference in vessel diameter or blood flow velocity when comparing successful RACs to that of the four that developed a final failure; however this may be attributed to the limited number of final failures that were observed.

There was also no difference in velocity patterns or in diameter in the RACs that failed compared to those that did not fail.

The conclusions from this study are threefold. Both the RA and UA experienced significant dilation after RAC insertion. The data suggested that vasodilation and increased blood flow around the catheter may help to prevent thrombosis and protect the function of the arterial catheter. In some patients, the peak blood flow velocity significantly decreased after insertion of a 20 g catheter, especially in RA with a small inner diameter. With the S9’s high-resolution ultrasound imaging abilities, in vivo observations were possible to reveal what caused RAC failure during the patient’s clinical course. Failures consisted primarily of tortuous vascular anatomy and RAC tip obstruction, thrombus formation on the RAC tip, and partial/complete thrombosis of the RA lumen.

Related Links:

SonoScape Medical corp.


New
Gold Member
X-Ray QA Meter
T3 AD Pro
New
Portable Color Doppler Ultrasound System
S5000
Radiology Software
DxWorks
Ultrasound Color LCD
U156W
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to MedImaging.net and get complete access to news and events that shape the world of Radiology.
  • Free digital version edition of Medical Imaging International sent by email on regular basis
  • Free print version of Medical Imaging International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of Medical Imaging International in digital format
  • Free Medical Imaging International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Radcal

Channels

Radiography

view channel
Image: The new X-ray detector produces a high-quality radiograph (Photo courtesy of ACS Central Science 2024, DOI: https://doi.org/10.1021/acscentsci.4c01296)

Highly Sensitive, Foldable Detector to Make X-Rays Safer

X-rays are widely used in diagnostic testing and industrial monitoring, from dental checkups to airport luggage scans. However, these high-energy rays emit ionizing radiation, which can pose risks after... Read more

MRI

view channel
Image: Artificial intelligence models can be trained to distinguish brain tumors from healthy tissue (Photo courtesy of 123RF)

AI Can Distinguish Brain Tumors from Healthy Tissue

Researchers have made significant advancements in artificial intelligence (AI) for medical applications. AI holds particular promise in radiology, where delays in processing medical images can often postpone... Read more

Nuclear Medicine

view channel
Image: Example of AI analysis of PET/CT images (Photo courtesy of Academic Radiology; DOI: 10.1016/j.acra.2024.08.043)

AI Analysis of PET/CT Images Predicts Side Effects of Immunotherapy in Lung Cancer

Immunotherapy has significantly advanced the treatment of primary lung cancer, but it can sometimes lead to a severe side effect known as interstitial lung disease. This condition is characterized by lung... Read more

General/Advanced Imaging

view channel
Image: Cleerly offers an AI-enabled CCTA solution for personalized, precise and measurable assessment of plaque, stenosis and ischemia (Photo courtesy of Cleerly)

AI-Enabled Plaque Assessments Help Cardiologists Identify High-Risk CAD Patients

Groundbreaking research has shown that a non-invasive, artificial intelligence (AI)-based analysis of cardiac computed tomography (CT) can predict severe heart-related events in patients exhibiting symptoms... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.