3D Printed Plastics Could Replace Metallic Collimators

By MedImaging International staff writers
Posted on 18 Nov 2019
3D printing of plastic collimators for external beam radiation therapy (EBRT) could improve accuracy and reduce dose delivery and collimator manufacturing time, claims a new study.

In order to develop the plastic collimators, researchers at Tomsk Polytechnic University (TPU; Russia), Moscow City Oncology Hospital No. 62 (Russia), and University Hospital Hamburg-Eppendorf (UKE; Germany) first used a numerical model to study the capability of high impact polystyrene (HIS) and acrylonitrile butadiene styrene (ABS) plastics to absorb an electron beam, and the required thickness and manufacturing method needed for the printed collimator to completely absorb the EBRT dose.

They then used the plastics to manufacture the first products through the method of layer-by-layer fused deposition modeling, using rapid prototyping. As the manufacturing process can affect crucial properties, such as material homogeneity (due to the presence of residual air-filled cavities), Monte Carlo simulations were used to determine electron depth dose distribution. The appropriate thickness for total absorption of 6 MeV electron beams was found tobe at least 4 cm, at least 8 cm for 12 MeV, and 11 cm for 20 MeV. The study was published in the August 2019 issue of Physica Medica.

“Metal collimators should be 1.6 cm thick to absorb the beam but, unlike metal, plastic does not have the same density and a number of other characteristics. We conducted a number of calculations and experiments to determine the thickness of a plastic product,” said senior author Sergei Stuchebrov, PhD, of the TPU Research School of High-Energy Physics. “For instance, we used special dosimeters, placed inside the plastic, to measure the depth distribution of the electron beam. The results can be used to further develop 3D printing procedures for medical electron beam profile formation.”

Collimators allow radiotherapy treatment (RT) flexibility in shielding organs-at-risk (OAR), while ensuring that the prescribed dose is delivered to the target. While in linear RT, a multi-leaf collimator (MLC) can be used to align the treatment field parallel to the radiation field and to the shape of the tumor, EBRT works from multiple directions, requiring fabrication of a patient-specific collimator using hand-crafted blocks.

Related Links:
Tomsk Polytechnic University
Moscow City Oncology Hospital No. 62
University Hospital Hamburg-Eppendorf



New
MRI Infusion Workstation
BeneFusion MRI Station
Ultra-Flat DR Detector
meX+1717SCC
X-Ray Illuminator
X-Ray Viewbox Illuminators
Digital X-Ray Detector Panel
Acuity G4
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to MedImaging.net and get complete access to news and events that shape the world of Radiology.
  • Free digital version edition of Medical Imaging International sent by email on regular basis
  • Free print version of Medical Imaging International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of Medical Imaging International in digital format
  • Free Medical Imaging International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

MRI

view channel
Image: Comparison showing 3T and 7T scans for the same participant (Photo courtesy of P Simon Jones/University of Cambridge)

Ultra-Powerful MRI Scans Enable Life-Changing Surgery in Treatment-Resistant Epileptic Patients

Approximately 360,000 individuals in the UK suffer from focal epilepsy, a condition in which seizures spread from one part of the brain. Around a third of these patients experience persistent seizures... Read more

Ultrasound

view channel
Image: Oloid-shaped magnetic endoscope (Photo courtesy of STORM Lab/University of Leeds)

Tiny Magnetic Robot Takes 3D Scans from Deep Within Body

Colorectal cancer ranks as one of the leading causes of cancer-related mortality worldwide. However, when detected early, it is highly treatable. Now, a new minimally invasive technique could significantly... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.