We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
GLOBETECH PUBLISHING LLC

Download Mobile App




MRI Provides Early Warning System for Glioblastoma Growth

By MedImaging International staff writers
Posted on 02 Oct 2024
Print article
Image: MRI-linac allows clinicians to see what’s going on in the brain for the first time (Photo courtesy of Sylvester Comprehensive Cancer Center)
Image: MRI-linac allows clinicians to see what’s going on in the brain for the first time (Photo courtesy of Sylvester Comprehensive Cancer Center)

A new study has demonstrated the potential of combining imaging with radiation to shape glioblastoma treatment in real time. The research is the first to quantify tumor changes in glioblastoma patients undergoing MRI-guided radiation therapy, a novel technique known as MRI-linear accelerator or MRI-linac, which integrates daily imaging with radiation. The study revealed that daily imaging can serve as an early detection system for tumor growth during treatment, offering a timelier signal than standard imaging. This finding suggests that MRI-linac could be used in the future to rapidly adapt treatment during radiation therapy.

Researchers at the University of Miami Sylvester Comprehensive Cancer Center (Miami, FL, USA) tracked 36 glioblastoma patients over a six-week course of daily radiation and MRI scans using MRI-linac. The data from these daily scans were then compared to traditional imaging methods, which involve a single MRI with contrast before radiation therapy and another MRI one month after the treatment concludes. While MRI-linac can be used with contrast agents, many patients have concerns about the frequent use of these heavy metals, so the study was conducted using non-contrast daily scans. Typically, brain radiation is guided by X-ray or CT scans to position the patient under the radiation beam, but these scans only show the position of the skull. MRI-linac, however, allows clinicians to observe changes within the brain itself.

The study published in the International Journal of Radiation Oncology – Biology – Physics, revealed that in 74% of participants, the MRI-linac imaging results aligned with standard pre- and post-treatment MRI scans, both of which assessed whether the tumors had grown, shrunk, or remained stable during radiation. In the remaining 26% of patients, MRI-linac detected tumor growth even when standard imaging suggested tumor shrinkage. Although daily MRI scans did not always match the contrast imaging results, they successfully identified all cases of true tumor growth. This indicates that MRI-linac could be used as an early signal of potential tumor growth during radiation therapy, which could then be confirmed through contrast imaging. The technology may ultimately enable faster adjustments to treatment based on real-time tumor changes.

Daily imaging with MRI-linac could also be valuable beyond detecting tumor growth. If a tumor is shrinking, the radiation field could be narrowed to more precisely target only cancerous tissue. Additionally, most glioblastoma patients undergo surgery before radiation, and the size of the surgical resection cavity, where the tumor was removed, often decreases as the brain heals. Monitoring this shrinkage over time and adjusting the radiation field accordingly could help protect healthy tissue. In this study, the researchers monitored changes in both tumor size and the surgical cavity. The research team plans future studies to explore MRI-linac’s ability to guide treatment decisions during radiation therapy for glioblastoma patients and other types of brain cancer. Since few clinics currently use MRI-linac for brain cancer treatment, this study is among the first to show that glioblastomas can change significantly during radiation. The researchers aim to leverage this knowledge to improve outcomes for patients with this often-deadly form of cancer.

New
Gold Member
X-Ray QA Meter
T3 AD Pro
New
Diagnostic Ultrasound System
MS1700C
New
Mini C-arm Imaging System
Fluoroscan InSight FD
Silver Member
Radiographic Positioning Equipment
2-Step Multiview Positioning Platform

Print article

Channels

Ultrasound

view channel
Image: A transparent ultrasound transducer-based photoacoustic-ultrasound fusion probe, along with images of a rat’s rectum and a pig’s esophagus (Photo courtesy of POSTECH)

Transparent Ultrasound Transducer for Photoacoustic and Ultrasound Endoscopy to Improve Diagnostic Accuracy

Endoscopic ultrasound is a commonly used tool in gastroenterology for cancer diagnosis; however, it provides limited contrast in soft tissues and only offers structural information, which reduces its diagnostic... Read more

General/Advanced Imaging

view channel
Image: The results of the eight-view 3D CT reconstruction from a public dataset (Photo courtesy of Medical Physics, doi.org/10.1002/mp.12345)

AI Model Reconstructs Sparse-View 3D CT Scan With Much Lower X-Ray Dose

While 3D CT scans provide detailed images of internal structures, the 1,000 to 2,000 X-rays captured from different angles during scanning can increase cancer risk, especially for vulnerable patients.... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.