Four Imaging Approaches Can Differentiate Malignant and Benign Breast Tumors

By MedImaging International staff writers
Posted on 10 Jul 2014
Imaging breast tumors using four approaches together, can better distinguish malignant breast tumors from those that are benign, compared with imaging using fewer approaches, and this may help avoid repeat breast biopsies.

The findings were published online June 24, 2014, in Clinical Cancer Research, a journal of the American Association for Cancer Research. “By assessing many functional processes involved in cancer development, a multiparameter PET/MRI [positron emission tomography/magnetic resonance imaging] of the breast allows for a better differentiation of benign and malignant breast tumors than currently used dynamic contrast-enhanced MRI [DCE-MRI)] by itself. Therefore, unnecessary breast biopsies can be avoided,” said Katja Pinker, MD, associate professor of radiology in the department of biomedical imaging and image-guided therapy at the Medical University of Vienna (Austria).

The new imaging technique, called multiparametric (MP) 18FDG (fluorodeoxyglucose) PET-MRI, which used four imaging approaches, was 96% accurate in distinguishing malignant breast tumors from those that were benign, and provided better results than combinations of two or three imaging approaches. The study estimates that this technique can cut unnecessary breast biopsies recommended by the typically used imaging modality, the DCE-MRI, by 50%.

“DCE-MRI is a very sensitive test for the detection of breast tumors, but is limited in visualizing the functional properties cancer cells acquire during development. Therefore, there is still room for improvement,” explained Dr. Pinker. “PET/MRI mirrors cancer biology and allows accurate diagnosis of breast cancer without a biopsy. Additionally, the more accurately we understand a tumor’s biology, the better we can tailor therapy to each breast cancer patient’s individual needs. Provided that a hospital is equipped with a PET/CT [computed tomography] and an MRI scanner or a combined PET/MRI, the technique we have described can be immediately implemented in clinics,” said Dr. Pinker.

The investigators recruited 76 patients to the study who had suspicious or inconclusive findings from a mammography or a breast ultrasonography. They performed a MP18FDG PET/MRI on all the patients. Furthermore, all patients’ breast tumor biopsies were evaluated by histopathology.

To determine the combination of imaging parameters that yielded the most accurate results, Dr. Pinker and colleagues combined the imaging data from two parameters, three parameters, and all four parameters. All two-parameter and three-parameter evaluations included DCE-MRI. All findings were compared with histopathology diagnosis to evaluate which combination was most efficient in making an accurate diagnosis. Of the 76 tumors, based on histopathology, 53 were malignant and 23 were benign.

The researchers found that none of the two- or three-parameter combinations reached the same level of sensitivity and specificity as the four-parameter method, which had an appropriate use criteria (AUC) of 0.935. (An AUC of 0.9 to 1 means the modality is excellent, and an AUC of 0.5 means the method is worthless.) “Performing a combined PET-MRI is currently less cost-effective than existing breast imaging methods,” said Dr. Pinker. “However, a significant reduction in unnecessary breast biopsies by using this combined method may improve the cost-effectiveness.”
MP18FDG PET-MRI allowed tumor imaging by four parameters: DCE-MRI, diffusion-weighted imaging (DW), three-dimensional (3D) 1H-magnetic resonance spectroscopic imaging (MRSI), and 18FDG-PET.

Related Links:

Medical University of Vienna



40/80-Slice CT System
uCT 528
Diagnostic Ultrasound System
MS1700C
Portable X-ray Unit
AJEX140H
Ultrasound Imaging System
P12 Elite
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to MedImaging.net and get complete access to news and events that shape the world of Radiology.
  • Free digital version edition of Medical Imaging International sent by email on regular basis
  • Free print version of Medical Imaging International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of Medical Imaging International in digital format
  • Free Medical Imaging International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.