Electronic Alerts on Abnormal Imaging Test Results Do Not Always Result in Timely Follow-Up

By MedImaging International staff writers
Posted on 20 Oct 2009
Print article
Abnormal results on outpatient imaging tests sometimes may not receive appropriate follow-up even when clinicians receive and read results in an advanced, integrated electronic medical record system, according to a recent report.

"Communication breakdown is consistently identified as a preventable factor in studies of adverse events and a significant contributor to outpatient diagnostic errors from a lack of follow-up of abnormal test results,” the investigators reported in their study, published in the September 28, 2009, issue of Archives of Internal Medicine, one of the JAMA/Archives journals. The high volume and number of transitions between clinicians in outpatient care makes timely communication especially difficult. For instance, a primary care physician may refer a patient with respiratory symptoms to undergo several laboratory and imaging tests and a pulmonary consultation. Any abnormal findings, such as a lung mass, would need to be communicated rapidly and effectively to all clinicians involved in treating the patient.

Some healthcare systems use electronic communication with alerts to notify clinicians who order imaging tests about critical abnormal results--an approach that may have advantages over a paper-based reporting system. "However, effective communication involves more than just information transfer-it requires a response from the recipient, such as taking follow-up action and acknowledging receipt of the information to the sender,” the investigators stated in their study.

Hardeep Singh, M.D., M.P.H., from Michael E. DeBakey Veterans Affairs Medical Center and Baylor College of Medicine, both based in Houston, TX, USA) examined critical imaging alert notifications in the outpatient setting of one Department of Veterans Affairs facility between November 2007 and June 2008. The researchers used tracking software to determine whether alerts about abnormal test results were read within two weeks, then reviewed medical records and contacted healthcare practitioners to determine whether timely follow-up actions (such as ordering a follow-up test or consultation) were taken within four weeks of the alert transmission.

Of 123,638 imaging tests (including X-rays, computed tomograpy [CT] scans, magnetic resonance imaging [MRI] and mammograms) performed during the study period, results from 1,196 (0.97%) generated alerts to the ordering clinician. Of these alerts, 217 (18.1%) were not acknowledged. Alerts were more likely to be unacknowledged if the ordering clinician was a trainee or if an alert was sent to more than one clinician (for example, when the ordering clinician was not the patient's primary care physician, and alerts were sent to both the specialist and the patient's regular physician).

Timely follow-up of abnormal results did not occur following 92 (7.7%) of all alerts, including 7.3% of alerts that were acknowledged and 9.7% of alerts that were unacknowledged. This follow-up was also less likely to occur when more than one clinician received the alert, but more apt to occur when a radiologist also reported concerns about the results verbally, either by phone or in person. "Nearly all abnormal test results lacking timely follow-up at four weeks were eventually found to have measurable clinical impact in terms of further diagnostic testing or treatment,” the authors stated.

"Our findings suggest that an electronic medical record that facilitates transmission and availability of critical imaging results to the healthcare provider through either automated notification or direct access of primary report does not eliminate the problem of missed test results even when one or more healthcare providers read the results,” the investigators concluded. "Therefore, even in the best of information systems that contain advanced notification features, patients with abnormal imaging results are vulnerable to ‘falling through the cracks.' This underscores the need for a multidisciplinary approach involving human-computer interaction and informatics to complement the benefits achieved by automated notification and the need for continuous monitoring procedures to ensure follow-up even when healthcare providers ‘acknowledge,' i.e., read abnormal results.”

Related Links:

Michael E. DeBakey Veterans Affairs Medical Center
Baylor College of Medicine


LED-Based X-Ray Viewer
Dixion X-View
Portable Color Doppler Ultrasound Scanner
DCU10
Ultrasound Scanner
TBP-5533
New
Mini C-arm Imaging System
Fluoroscan InSight FD

Print article

Channels

Ultrasound

view channel
Image: The addition of POC ultrasound can enhance first trimester obstetrical care (Photo courtesy of 123RF)

POC Ultrasound Enhances Early Pregnancy Care and Cuts Emergency Visits

A new study has found that implementing point-of-care ultrasounds (POCUS) in clinics to assess the viability and gestational age of pregnancies in the first trimester improved care for pregnant patients... Read more

Nuclear Medicine

view channel
Image: PSMA-PET/CT images of an 85-year-old patient with hormone-sensitive prostate cancer (Photo courtesy of Dr. Adrien Holzgreve)

Advanced Imaging Reveals Hidden Metastases in High-Risk Prostate Cancer Patients

Prostate-specific membrane antigen–positron emission tomography (PSMA-PET) imaging has become an essential tool in transforming the way prostate cancer is staged. Using small amounts of radioactive “tracers,”... Read more

General/Advanced Imaging

view channel
Image: Automated methods enable the analysis of PET/CT scans (left) to accurately predict tumor location and size (right) (Photo courtesy of Nature Machine Intelligence, 2024. DOI: 10.1038/s42256-024-00912-9)

Deep Learning Based Algorithms Improve Tumor Detection in PET/CT Scans

Imaging techniques are essential for cancer diagnosis, as accurately determining the location, size, and type of tumors is critical for selecting the appropriate treatment. The key imaging methods include... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.