Noninvasive Fusion Imaging Technique May Reduce Number of Breast Biopsies

By MedImaging International staff writers
Posted on 02 Aug 2010
Print article
Image: Quing Zhu, professor of electrical and computer engineering, with her device for early detection of breast cancer lesions (photo courtesy of Peter Morenus).
Image: Quing Zhu, professor of electrical and computer engineering, with her device for early detection of breast cancer lesions (photo courtesy of Peter Morenus).
By combining two comparatively inexpensive technologies based on sound and light waves, researchers hope to lower the rate at which women undergo breast biopsies for suspicious lesions.

"The goal of our study was to investigate the potential of diffuse optical tomography in the near-infrared spectrum with ultrasound localization as a means of differentiating early-stage cancers from benign lesions of the breast,” said lead researcher Quing Zhu, Ph.D., professor of bioengineering at the University of Connecticut (Storrs, USA).

When mammography and ultrasound cannot determine whether a suspicious breast lesion is malignant or benign, physicians typically recommend a needle biopsy to extract samples of the suspicious tissue for laboratory testing. In current clinical practice, 70% - 80% of biopsies performed reveal benign lesions, leading to unnecessary expense and worry for women.

Diffuse optical tomography (DOT) is an emerging noninvasive imaging technique that measures light absorption within tissue to quantify blood content (hemoglobin level) and blood oxygen levels. Because cancerous lesions have many more blood vessels than normal tissue, hemoglobin levels can help distinguish malignant from benign lesions.

In Dr. Zhu's study, 178 consecutive women underwent ultrasound-guided DOT on a previously identified solid lesion, followed by a biopsy. The study, which included women between the ages of 21 and 89 years, was conducted between 2004 and 2008 at the University of Connecticut Health Center and Hartford Hospital, both in Hartford, CT, USA.

Performing ultrasound-guided DOT involves the use of a handheld probe consisting of a commercial ultrasound transducer located in the middle and an optical source and detector fibers around the periphery. Once ultrasound locates the lesion, DOT is performed by shining infrared light into the area and measuring light absorption at two optical wavelengths. "Infrared light penetrates deep into tissue, up to 4 cm,” Dr. Zhu said.

Researchers computed total hemoglobin levels from the light absorption measured at two wavelengths and correlated the measurements with biopsy results. Laboratory examination of tissue samples revealed two in situ carcinomas, 35 carcinomas that measured less than 2 cm, 24 carcinomas greater than 2 cm, and 114 benign lesions. "Both maximum and average total hemoglobin levels were significantly higher in the malignant groups than in the benign group,” Dr. Zhu said.

The sensitivity and specificity of the technique (92% and 93%, respectively) were greatest when assessing tumors less than 2 cm in size. "Based on our results, we believe that ultrasound-guided diffuse optical tomography holds promise as an adjunct to diagnostic mammography and ultrasound for distinguishing early-stage invasive breast cancers from benign lesions,” Dr. Zhu said. "We expect this technology will be used to help radiologists evaluate small to intermediate size lesions that are harder to diagnose with conventional imaging technologies.”

Ultrasound and near infrared procedures cost considerably less than magnetic resonance imaging (MRI), another methodology used to assess suspicious breast lesions that cannot be diagnosed using mammography.

The next phase of Dr. Zhu's research is to design multi-institution clinical trials for ultrasound-guided DOT. The study's findings on ultrasound-guided optical tomography were published in the online edition and the August 2010 print issue of the journal Radiology.

Related Links:

University of Connecticut



New
Gold Member
X-Ray QA Meter
T3 AD Pro
New
Multi-Use Ultrasound Table
Clinton
Imaging Table
CFPM201
Ultrasound Color LCD
U156W

Print article
Radcal

Channels

Radiography

view channel
Image: The new X-ray detector produces a high-quality radiograph (Photo courtesy of ACS Central Science 2024, DOI: https://doi.org/10.1021/acscentsci.4c01296)

Highly Sensitive, Foldable Detector to Make X-Rays Safer

X-rays are widely used in diagnostic testing and industrial monitoring, from dental checkups to airport luggage scans. However, these high-energy rays emit ionizing radiation, which can pose risks after... Read more

MRI

view channel
Image: The scans revealed a new dimension of brain network organization in humans (Photo courtesy of Georgia State University/TReNDS Center Research)

New Approach Identifies Signatures of Chronic Brain Disorders Using fMRI Scans

Traditional studies of brain function, often using fMRI scans to detect brain activity patterns, have shown promise in identifying changes in individuals with chronic brain disorders like schizophrenia.... Read more

Nuclear Medicine

view channel
Image: Example of AI analysis of PET/CT images (Photo courtesy of Academic Radiology; DOI: 10.1016/j.acra.2024.08.043)

AI Analysis of PET/CT Images Predicts Side Effects of Immunotherapy in Lung Cancer

Immunotherapy has significantly advanced the treatment of primary lung cancer, but it can sometimes lead to a severe side effect known as interstitial lung disease. This condition is characterized by lung... Read more

General/Advanced Imaging

view channel
Image: Cleerly offers an AI-enabled CCTA solution for personalized, precise and measurable assessment of plaque, stenosis and ischemia (Photo courtesy of Cleerly)

AI-Enabled Plaque Assessments Help Cardiologists Identify High-Risk CAD Patients

Groundbreaking research has shown that a non-invasive, artificial intelligence (AI)-based analysis of cardiac computed tomography (CT) can predict severe heart-related events in patients exhibiting symptoms... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.